n
No dehumidification. Compressor does not run but
blower runs with fan switch AUTO and humidity control
turned to ON.
1. Defrost thermostat open, ambient temperature too low.
2. Loose connection in compressor circuit.
3. Defective compressor overload.
4. Defective compressor or compressor run capacitor.
n
Blower runs with fan switch AUTO but compressor
cycles on & off.
1. Low ambient temperature and/or humidity causing unit
to cycle through defrost mode.
2. Defrost thermostat defective.
3. Defective compressor overload.
4. Defective compressor.
n
Blower does not run with fan switch in either position.
Compressor runs briefly but cycles on and off.
1. Loose connection in blower circuit.
2. Obstruction prevents impeller rotation.
3. Defective blower.
4. Defective blower switch.
n
Evaporator coil frosted continuously, low
dehumidifying capacity.
1. Dirty air lter or air ow restricted.
2. Defrost thermostat loose or defective.
3. Low refrigerant charge.
If none of the above has fixed the issue, call
technical support at 1-800-533-7533, Ext. 8459.
9. Service Parts List -
Call your dealer or 1-800-533-7533.
Part No Description
4034011-02 Evaporator
4034093 Capillary Tubes
4028089 Compressor
1970010 Compressor Relay
4029510 Filter/drier
4034109 Condensor
4032196 Impeller
4033032-03 35mfd 370V Capacitor - Compressor
4033031-02 5mfd 370V Capacitor - Impeller
4026221 Leveling Foot
4031376 Defrost Thermostat
4027172 Humidity Controller
4025560 Fan Switch
SANTA FE ADVANCE2 OWNER’S AND INSTALLER’S MANUAL
6
Santa Fe Advance2 Installer’s & Owner’s Manual
11. Wiring Diagram
10. Accessory/Replacement Parts -
Call your dealer or order online.
4031062 Filter MERV 8
4033036 Filters 4-Pack, MERV 8
4033037 Filters 12-Pack, MERV 8
4028616 Caster Kit
4033038 Pump Kit
4033039 Duct Kit
4026969 10" Flex Duct
4022126 10" Flex Duct (Insulated)
4020175 Remote Dehumidistat
Comments to this Manuals